lc-ms/ms

  1. madman

    E2 Infinity and Beyond: Advancing Estradiol Testing with the Cobas i 601 Analyzer

    MSACL 2025 Abstract Matthew R Chappell (1), Meghan N Bradley (1), Matthew L Crawford (1), Sven Groesgen (2), Philippe Metz (2), Russell P Grant (1) (1) Center for Esoteric Testing, Labcorp, Burlington NC 27215, (2) Roche Diagnostics GmbH, Mannheim, Germany Abstract INTRODUCTION The...
  2. madman

    Diagrams: Accurate Androgen and Estrogen Measurement in Human Serum and Plasma

    * Probably the most challenging forms to quantify, due to their relatively low concentrations are the so called free forms. The free forms of all the hormones (shown in Figs. 1–3) are the hormones not bound to proteins, or conjugated to other molecules (see Fig. 2) and are biologically active...
  3. madman

    Serum Free Testosterone: Precision LC-MS/MS for PCOS Diagnosis

    * A standardized ED method is recommended to effectively separate FT from the serum matrix. * With the rapid development of liquid chromatography-tandem mass spectrometry (LC-MS/MS), the ED separation combined with LC-MS/MS has become the “gold standard” for quantifying FT [4]. * Serum FT...
  4. madman

    Evaluation of five multi steroid LC-MS/MS methods used for routine clinical analysis

    Abstract Objectives A mass spectrometry (LC-MS/MS)--based interlaboratory comparison study was performed for nine steroid analytes with five participating laboratories. The sample set contained 40 pooled samples of human serum generated from preanalyzed leftovers. To obtain a well-balanced...
  5. madman

    Serum INSL3, testosterone, and LH in testicular suppression

    Serum INSL3, LH, and testosterone levels were studied in different contexts. After Sustanon treatment, testosterone initially increased but then rapidly decreased due to clearance and suppressed secretion. INSL3 complemented testosterone measurements, reflecting immediate Leydig cell function...
  6. madman

    Using mass spectrometry to overcome the longstanding inaccuracy of a commercially-available clinical T immunoassay

    ABSTRACT Accurate measurement of testosterone is important for the diagnosis of gonadal disorders in men, women, and children. Testosterone measurement has limited accuracy at low concentrations by most commercially available immunoassays. We aimed to develop an LC-MS/MS assay to address the...
  7. madman

    LC-MS/MS assay for the quantification of allopregnanolone and its progesterone-derived isomers, precursors

    Development and validation of an LC-MS/MS assay for the quantification of allopregnanolone and its progesterone-derived isomers, precursors, and cortisol/cortisone in pregnancy Abstract Neuroactive steroids are potent neuromodulators that play a critical role in both maternal and fetal health...
  8. G

    Total testosterone MS and Nandrolone

    Is Total T MS panel specific enough to recognize a testosterone molecule from a nandrolone molecule? I know the standard non sensitive Total T panel can’t differentiate test and nandrolone and will add them together, and the Total T LC/MS/MS panel is specific enough to know the difference and...
  9. madman

    Is LC-MS/MS the Magic Bullet? - What the Endocrinologist Should Know

    Abstract Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool that is changing the way we analyze steroids in the clinical laboratory. It offers positive compound identification to enable the unequivocal identification of a compound free from interference. LC-MS/MS is...

lc-ms/ms

lc-ms/ms

Members online

Beyond Testosterone Podcast

Back
Top